北京Announcement of Pre Qualification for Supply and Installation of Distribution Room Equipment for the Overall Renovation and Reinforcement Project of Jingyuan Building and Dangerous Building Construction
CODE
Click to view
Amount
Click to view
Bidding Unit
Click to view
Bidding TEL
Click to view
Agency
Click to view
Agency TEL
Click to view
To view hidden content (*), please log in first
Detailed Content Template Start -------------------------------------------------------------------------------? Announcement Content: The overall renovation and dangerous building reinforcement project of Jingyuan Building, including the supply and installation of power distribution room equipment, has been approved for construction by the Development and Reform Commission of Xicheng District, Beijing. The construction site is located in Shuanghuai Village, Nanheng West Street, with Nanheng West Street to the north, Pen Er Hutong to the east, and Shuanghuai Village to the south and west. The construction funds come from government investment (local), with a contribution ratio of 100%. The supply and installation of power distribution room equipment for the overall decoration and renovation of Jingyuan Building and the reinforcement of dangerous buildings required for the construction of Tit2end have met the bidding conditions. The tenderer is Beijing Urban Construction Group Co., Ltd., and the bidding agency is Beijing Mingjia Consulting Services Co., Ltd. The bidding is now open for public bidding, and interested potential bidders (hereinafter referred to as the applicant) are invited to submit pre qualification applications. Tit2end2. Project Overview and Bidding Scope 2. Subcontracting Project Overview and Bidding Scope end2.1 Name of Subcontracting Project for this Specialty: Jingyuan Building Overall Decoration and Renovation, and Dangerous Building Reinforcement Project - Supply and Installation of Power Distribution Room Equipment 2.2 Construction Scale of Subcontracting Project for this Specialty: The total decoration area is approximately 39859.4 square meters, with an estimated contract price of 648 yuan. 2.3 Construction Location of Subcontracting Project for this Specialty: Shuanghuai Li Community, Nanhengxi Street to the north, Pen'er Hutong to the east, and Shuanghuai Li Community to the south and west. 2.4 Construction Period Requirements for Subcontracting Project for this Specialty: 64 calendar days. 2.5 Bidding Scope of Subcontracting Project for this Specialty: 10KV High Voltage Cable Engineering and High Foundation Power Distribution Room Engineering. According to the construction drawings of the design institute, the project will be completed. 10KV high voltage cabinet, dry-type transformer, low voltage distribution cabinet, low voltage capacitor cabinet, harmonic control cabinet, DC screen, dense busbar bridge Supply and installation of 10KV cables (from high-voltage ring main unit to transformer) and cable terminals, indoor grounding network installation and connection with the main grounding network, simulation board and other equipment materials (including laying high-voltage insulation rubber pads). Manufacturing and installation of channel steel equipment foundation; Including the production and installation of supports and hangers for high-voltage cables, as well as rat traps (meeting specifications and functional requirements). Supply and installation of high-voltage cable trays and control cable trays. Supply and installation of high-voltage cable trays in transformer and distribution rooms. 2.6 Other voltages are 10KV, with a total capacity of 3760KVA. Tit2end3. Qualification Requirements for Applicants: Qualification Requirements for Bidders: End3.1 Qualification Pre Qualification Requirements for Subcontracting Projects in this Major: Applicants must possess Level 3 [New] or higher qualifications for professional contracting of power transmission and transformation engineering, with recent/year/performance, and corresponding construction capabilities in personnel, equipment, funds, etc. Among them, the applicant's proposed project manager must have a registered constructor in the field of mechanical and electrical engineering